Heat Source Watts BTU/h Deg K Deg F Data Notes Test Criteria: Maintain house temperature at X deg. F in still outside air without sunshine.
Baseline value no heat 0 0 292 66.5 projected
De-Humidfier 700 2388.499 285 53 measured Running dehumidifier 700W at cloudy 53deg  outdoor and 69  indoor on thermostat, 67.5 on display at equilibrium.
Wood Stove @ 250 F 1644.077 5609.823 279 42 projected untested
Single 8ft elec. baseboard 2000 6824.284 273 31.5 measured Outdoor temp at 31.5 rain/snow, no wind at night.  temp on main thermostat at 68, 66.5 on thermometer.
Wood Stove @ 300 F 2390.271 8155.943 267 20 projected untested
Wood Stove @ 350 F 3299.292 11257.65 261 10 projected untested
2        8ft elec. baseboard 4000 13648.57 255 0 projected untested
Wood Stove @ 400 F 4393.264 14990.44 249 -11 projected untested
Wood Stove @ 450 F 5695.719 19434.6 243 -17 measured tested to be -8 in still air at night, house holding at 68
Wood Stove @ 500 F 7231.601 24675.25 236 -35 projected untested
Data from stove radiational heat output chart.
Stove       
Surface Stove Body
Temp heat Rad. Radiation Freq
T  F T  K Intens W Lambda uM peak
70 294.2611 739.7139 <--BaseVal
       
100 310.9278 182.3699 9.320492
150 338.7056 558.7252 8.556104
200 366.4833 1039.996 7.90759
250 394.2611 1644.077 7.350459
300 422.0389 2390.271 6.866666
350 449.8167 3299.292 6.442625
400 477.5944 4393.264 6.06791
450 505.3722 5695.719 5.734387
500 533.15 7231.601 5.435618
550 560.9278 9027.262 5.166441
600 588.7056 11110.46 4.922665